Factory Wholesale Refrigerant Gas R410a in 11.3KG Cylinder
11.3KG R410A | Certification:CE | ||||
| Cylinder | Height | Diameter | Thickness | |
420mm | 241mm | 1.5mm | |||
Material | Capacity | Weight | |||
DC04 | 13.3L | 3.5kg | |||
Working Pressure | Testing Pressure | Filling Gas | |||
2.8Mpa | 3.45Mpa | R410A/R32 | |||
Gas Purity | 99.91%-99.97% | ||||
Gas N.W. | 11.3KG/25lb | ||||
Packing | carton size 24.5*24.5*42.5cm | ||||
Packing, Payment and Delivery | |||||
Packing | 1 cylinder/carton, disposable cylinder, OEM design on carton | ||||
Loading | 1150 cylinders/20ft container, mixing with other refrigerant gas is supported | ||||
Payment | Normally By T/T 30% as deposit, and the 70% balance against copy of B/L | ||||
Delivery | within 20 days after receipt of deposit and confirm of carton design | ||||
| |||||
Comparative analysis of the characteristics of R410A and R32.
1. Thermophysical properties: R32 charging volume can be reduced, only 0.71 times that of R410A. The working pressure of R32 system is higher than R410A, but the maximum increase is not more than 2.6%, which is equivalent to the pressure requirement of R410A system, and R32 system exhausts Compared with R410A, the temperature rises up to 35.3℃.
2. Environmental protection characteristics: ODP value (ozone depletion potential value) is 0, but R32's GWP value (global warming potential value) is moderate, compared with R22, the CO2 emission reduction ratio can reach 77.6%, while R410A is only 2.5% , It is significantly better than R410A in terms of CO2 emission reduction.
3. Safety: Both R32 and R410A are non-toxic, while R32 is combustible. Among several alternatives to R22, R32 and R290, R32 has the highest lower combustion limit, LFL. Although R290 is the most environmentally friendly, it is highly flammable and has a safety level of A3. Therefore, it is required to only charge air conditioners within 2p, and large number air conditioners are restricted.
4. Cycle performance: In terms of theoretical cycle performance, the cooling capacity of the R32 system is 12.6% higher than that of R410A, the power consumption increases by 8.1%, and the overall energy saving is 4.3%. The experimental results also show that the refrigeration system using R32 has a slightly higher energy efficiency ratio than R410A .
R410A refrigerant composition: R32, R125
Mole percentage: R32 accounts for 70%, R125 accounts for 30%
Mass percentage: R32 accounts for 50%, R125 accounts for 50%
UN NO:3163
CAS NO: 354-33-6,75-10-5
Refrigerant Freon Workshop and Shipment Glance
Freon accident risk:
1. Freon itself is non-toxic and a suffocating gas. Freon is heavier than air. After a leak, it will stay in a low and poorly ventilated place. When it mixes with air to a certain concentration, it will cause hypoxia in the environment. Staying in this environment can cause suffocation due to lack of oxygen. Excessive inhalation or long time can inhibit respiratory function and cause coma or even death.
2. Freon can decompose to produce toxic and harmful gases such as phosgene, hydrogen chloride, hydrogen fluoride, etc. when it meets an open flame and under the action of water vapor, which can cause poisoning.
3. The human body directly contacts the liquid freon, which can cause frostbite.
4. If the container or gas cylinder storing Freon encounters high heat, the internal pressure increases, and there is a danger of cracking and physical explosion.
Refrigerant Gas R410a | |
Physical Properties | |
Molecular Weight | 72.58 |
Boiling Point | 101.3KPa(° C) -51.6 |
Freezing Point | N/M |
Density 30° C(kg/m3) | 1038 |
Critical Temperature (° C) | 72.5 |
Critical Pressure (MPa) | 4.95 |
ODP | 0 |
GWP | 2000 |
Quality Index | |
Purity | ≥99.90% |
Water content | ≤0.001% |
Acidity | ≤0.00001% |
Evaporation residue | ≤0.01% |
Chloride content | ≤0.0001% |
Appearance | Colorless and clear |
Odor | Odorless |
Application | |
As long-term substitute for R-twenty-two, R410A is used mainly in the conditioners and refriger-anting systems. | |
Packing, Payment and Delivery | |
Packing | 1. Disposable cylinder: 11.3KG/25lb |
2. Refillable cylinder such as 12L/14L/60L etc.. | |
3. ISO-TANK | |
MOQ | 20'GP |
Payment | 1)By T/T 30% as deposit, the 70% balance against copy of B/L |
2)L/C payment term is also negotiable | |
Delivery | 20-25days after receiving the deposit |
About Sample | |
Sample is ok, but refrigerant is dangerous goods in law, ship agent will not accept mixed stuffing with other goods, so the high sea freight and delivery cost is better been taken into consideration. |
HFC Refrigerant HCFC Refrigerant HC Refrigerant Mapp Gas Helium Gas