Availability: | |
---|---|
Quantity: | |
Ningbo, China
USD 20 - USD 30 / Bottle
100 bottles
L/C, T/T
5.5KG cylinder, ton tank, ISO tank
2.1 Inflammable Gas
R290 Propane
74-98-6
1978
Manufacturer of 5.5KG Frioflor Brand R290 Propane Refrigerant Gas
Chemical Data of Refrigerant R290 Propane Gas | |
Physical Properties | |
Molecular Formula | CH3CH2CH3 |
Molecular Weight | 44.1 |
Boiling Point ºC | -42.1 |
Freezing Point | N/M |
Critical Temperature (ºC) | 96.6 |
Critical Pressure (MPa) | 4.248 |
ODP | 0 |
GWP | 3.3 |
Quality Index | |
Purity | ≥ 99.90% |
Sulfur content ppm by weight | less than 1.0 |
Water content ppm by weight | less than 10 |
Acidity ppm by weight | less than 1.0 |
Evaporation residue | ≤ 0.01% |
Appearance | Colorless and clear |
Odor | Odorless |
Application | |
for refrigerant, for central air conditioning,heat pump, air conditoning and other small household refrigeration system, replacement of R22 | |
Packing, Payment and Delivery | |
Packing | 1. Small Can 300g/360g/380g |
2. Disposable cylinder: 5.5KG/13.4L, 9.5KG/22.3L | |
2. Refillable cylinder 48KG/118L,164KG/400L,328KG/800L etc. | |
3. ISO-TANK 10T/24m3 | |
MOQ | 20'GP |
Payment | 1)By T/T 30% as deposit, the 70% balance against copy of B/L |
2)L/C payment term is also negotiable | |
Delivery | 20-25days after receiving the deposit |
About Sample | |
Samples is ok, but refrigerant is dangerous goods in law, ship agent will not accept mixed stuffing with other goods, so the high sea freight and delivery cost is better been taken into consideration |
Comparison of R32 and R290
1. R290 and R32 have a relatively small amount of charge, the ODP value is 0, the GWP value is also much smaller than R22, the security level of R32 is A2, and the security level of R290 is A3.
2. R290 is more suitable for medium and high temperature air conditioning systems than R32. Pressure resistance design of R32 is higher than R290, and R32 has lower flammability than R290.
3. The dynamic viscosity of R290 is less than R32, and the pressure drop of the system heat exchanger is less than R32, which helps to improve the efficiency of the system.
4. R32 unit volume refrigeration capacity is about 87% higher than R290, R290 system should use a larger displacement compressor under the same refrigeration capacity.
5. R32 has a higher exhaust temperature, and the pressure ratio of the R32 system is about 7% higher than that of the R290 system, and the overall energy efficiency ratio of the system is about 3.7% lower.
6. The pressure drop of the R290 system heat exchanger is less than R32, which helps to improve system performance. But its flammability is far greater than R32, and has higher investment in safety design.
Manufacturer of 5.5KG Frioflor Brand R290 Propane Refrigerant Gas
Chemical Data of Refrigerant R290 Propane Gas | |
Physical Properties | |
Molecular Formula | CH3CH2CH3 |
Molecular Weight | 44.1 |
Boiling Point ºC | -42.1 |
Freezing Point | N/M |
Critical Temperature (ºC) | 96.6 |
Critical Pressure (MPa) | 4.248 |
ODP | 0 |
GWP | 3.3 |
Quality Index | |
Purity | ≥ 99.90% |
Sulfur content ppm by weight | less than 1.0 |
Water content ppm by weight | less than 10 |
Acidity ppm by weight | less than 1.0 |
Evaporation residue | ≤ 0.01% |
Appearance | Colorless and clear |
Odor | Odorless |
Application | |
for refrigerant, for central air conditioning,heat pump, air conditoning and other small household refrigeration system, replacement of R22 | |
Packing, Payment and Delivery | |
Packing | 1. Small Can 300g/360g/380g |
2. Disposable cylinder: 5.5KG/13.4L, 9.5KG/22.3L | |
2. Refillable cylinder 48KG/118L,164KG/400L,328KG/800L etc. | |
3. ISO-TANK 10T/24m3 | |
MOQ | 20'GP |
Payment | 1)By T/T 30% as deposit, the 70% balance against copy of B/L |
2)L/C payment term is also negotiable | |
Delivery | 20-25days after receiving the deposit |
About Sample | |
Samples is ok, but refrigerant is dangerous goods in law, ship agent will not accept mixed stuffing with other goods, so the high sea freight and delivery cost is better been taken into consideration |
Comparison of R32 and R290
1. R290 and R32 have a relatively small amount of charge, the ODP value is 0, the GWP value is also much smaller than R22, the security level of R32 is A2, and the security level of R290 is A3.
2. R290 is more suitable for medium and high temperature air conditioning systems than R32. Pressure resistance design of R32 is higher than R290, and R32 has lower flammability than R290.
3. The dynamic viscosity of R290 is less than R32, and the pressure drop of the system heat exchanger is less than R32, which helps to improve the efficiency of the system.
4. R32 unit volume refrigeration capacity is about 87% higher than R290, R290 system should use a larger displacement compressor under the same refrigeration capacity.
5. R32 has a higher exhaust temperature, and the pressure ratio of the R32 system is about 7% higher than that of the R290 system, and the overall energy efficiency ratio of the system is about 3.7% lower.
6. The pressure drop of the R290 system heat exchanger is less than R32, which helps to improve system performance. But its flammability is far greater than R32, and has higher investment in safety design.