Availability: | |
---|---|
Quantity: | |
R507
FRIOFLOR
Ningbo, China
USD 35 - USD 55 / cylinder
300 cylinders
L/C, T/T
11.3KG Disposable Cylinder or Others
2.2
50% of R143a and 50% of R125
354-33-6
3163
11.3KG R507 | Certification:DOT/KGS/CE | ||||
![]() | Cylinder | Height | Diameter | Thickness | |
420mm | 240.6mm | 1.2mm | |||
Material | Capacity | Weight | |||
DC01 | 13.3L | 3.02kg | |||
Working Pressure | Testing Pressure | Filling Gas | |||
2.2Mpa | 2.7Mpa | R507 | |||
Gas Purity | 99.91%-99.97% | ||||
Gas N.W. | 11.3KG/25lb | ||||
Packing | carton size 24.5*24.5*42.5cm | ||||
Packing, Payment and Delivery | |||||
Packing | 1 cylinder/carton, disposable cylinder,neutral graphic design packing | ||||
Loading | 1140 cylinders/20ft container | ||||
Payment | Normally By T/T 30% as deposit, and the 70% balance against copy of B/L | ||||
Delivery | within 20 days after receipt of deposit and confirm of carton design | ||||
![]() | |||||
As one of the main manufacturers of refrigerant gas in China, we have the following advantage over other companies:
1. We have our own labs to guarantee the gas purity 99.93%
2. REACH certificate for Europe is available if necessary
3.We have our own corporated company for production of cylinders.
4. The cylinders have CE,KGS and DOT certificate, small cans have DOT certificate
5. We have R32,R152,R22,R134A,R410A,R407C,R404A,R290,R600A etc…
FRIOFLOR R507 is a blend of HFC Refrigerants commonly used as coolant in medium and low temperature commercial refrigeration systems and offers excellent performance replacing refrigerant R22 and R502 gas.
11.3KG R507 | Certification:DOT/KGS/CE | ||||
![]() | Cylinder | Height | Diameter | Thickness | |
420mm | 240.6mm | 1.2mm | |||
Material | Capacity | Weight | |||
DC01 | 13.3L | 3.02kg | |||
Working Pressure | Testing Pressure | Filling Gas | |||
2.2Mpa | 2.7Mpa | R507 | |||
Gas Purity | 99.91%-99.97% | ||||
Gas N.W. | 11.3KG/25lb | ||||
Packing | carton size 24.5*24.5*42.5cm | ||||
Packing, Payment and Delivery | |||||
Packing | 1 cylinder/carton, disposable cylinder,neutral graphic design packing | ||||
Loading | 1140 cylinders/20ft container | ||||
Payment | Normally By T/T 30% as deposit, and the 70% balance against copy of B/L | ||||
Delivery | within 20 days after receipt of deposit and confirm of carton design | ||||
![]() | |||||
As one of the main manufacturers of refrigerant gas in China, we have the following advantage over other companies:
1. We have our own labs to guarantee the gas purity 99.93%
2. REACH certificate for Europe is available if necessary
3.We have our own corporated company for production of cylinders.
4. The cylinders have CE,KGS and DOT certificate, small cans have DOT certificate
5. We have R32,R152,R22,R134A,R410A,R407C,R404A,R290,R600A etc…
FRIOFLOR R507 is a blend of HFC Refrigerants commonly used as coolant in medium and low temperature commercial refrigeration systems and offers excellent performance replacing refrigerant R22 and R502 gas.
Refrigerant R507 Gas | |
Physical Properties | |
Molecular Weight | 98.86 |
Boiling Point | 101.3KPa(° C) -47.1 |
Freezing Point | N/M |
Density 30° C(kg/m3) | 1021.9 |
Critical Temperature (° C) | 70.9 |
Critical Pressure (MPa) | 3.79 |
ODP | 0 |
GWP | 3900 |
Quality Index | |
Purity | ≥ 99.90% |
Water content | ≤ 0.001% |
Acidity | ≤ 0.00001% |
Evaporation residue | ≤ 0.01% |
Chloride content | ≤0.0001% |
Appearance | Colorless and clear |
Odor | Odorless |
Application | |
it is substitute for R502, used mainly in the low temperature refrigerating systems. | |
Packing, Payment and Delivery | |
Packing | 1. Disposable cylinder: 11.3kg(25lbs) |
2. Refillable cylinder such as 12L/14L/60L etc.. | |
3. ISO-TANK | |
MOQ | 20'GP |
Payment | 1)By T/T 30% as deposit, the 70% balance against copy of B/L |
2)L/C payment term is also negotiable | |
Delivery | 20-25days after receiving the deposit |
About Sample | |
Samples is ok, but refrigerant is dangerous goods in law, ship agent will not accept mixed stuffing with other goods, so the high sea freight and delivery cost is better been taken into consideration |
Refrigerant R507 Gas | |
Physical Properties | |
Molecular Weight | 98.86 |
Boiling Point | 101.3KPa(° C) -47.1 |
Freezing Point | N/M |
Density 30° C(kg/m3) | 1021.9 |
Critical Temperature (° C) | 70.9 |
Critical Pressure (MPa) | 3.79 |
ODP | 0 |
GWP | 3900 |
Quality Index | |
Purity | ≥ 99.90% |
Water content | ≤ 0.001% |
Acidity | ≤ 0.00001% |
Evaporation residue | ≤ 0.01% |
Chloride content | ≤0.0001% |
Appearance | Colorless and clear |
Odor | Odorless |
Application | |
it is substitute for R502, used mainly in the low temperature refrigerating systems. | |
Packing, Payment and Delivery | |
Packing | 1. Disposable cylinder: 11.3kg(25lbs) |
2. Refillable cylinder such as 12L/14L/60L etc.. | |
3. ISO-TANK | |
MOQ | 20'GP |
Payment | 1)By T/T 30% as deposit, the 70% balance against copy of B/L |
2)L/C payment term is also negotiable | |
Delivery | 20-25days after receiving the deposit |
About Sample | |
Samples is ok, but refrigerant is dangerous goods in law, ship agent will not accept mixed stuffing with other goods, so the high sea freight and delivery cost is better been taken into consideration |